Certification |
EMC certification Safety certification Manufacturing certification |
Chassis material |
Metal |
Static power consumption [W] |
Kas.14 |
Dimensions without packaging (H x W x D) [mm(in.)] |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442 mm x 160 mm (1.72 in. x 17.40 in. x 6.30 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442 mm x 167 mm (1.72 in. x 17.40 in. x 6.57 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] |
90.0 mm x 550.0 mm x 260.0 mm (3.54 in. x 21.65 in. x 10.24 in.) |
Chassis height [U] |
1 |
Installation type |
Rack mounting,Desk mounting,Wall mounting |
Weight without packaging [kg(lb)] |
1.97 (4.34) |
Weight with packaging [kg(lb)] |
2.76 kg (6.08 lb) |
Typical power consumption [W] |
21.32 |
Typical heat dissipation [BTU/hour] |
72.75 |
Maximum power consumption [W] |
21.Eyl |
Maximum heat dissipation [BTU/hour] |
74.72 |
MTBF [years] |
59.31 |
MTTR [hours] |
2 |
Availability |
> 0.99999 |
Maximum number of physical ports on the entire device |
28 |
Maximum number of 2.5GE ports |
4 |
Maximum number of GE ports |
28.Oca |
Maximum number of FE ports |
28 |
Long-term operating temperature [°C(°F)] |
–5°C to +40°C (41°F to 104°F) at an altitude of 0-1800 m (0-5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). |
Storage temperature [°C(°F)] |
–40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] |
5% RH to 95% RH (non-condensing) |
Long-term operating altitude [m(ft.)] |
0–5000 m (0–16404 ft.) |
Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Power supply mode |
AC built-in |
Rated input voltage [V] |
AC input: 100–240 V AC; 50/60 Hz |
Input voltage range [V] |
AC input: 90 V AC to 264 V AC; 45 Hz to 65 Hz |
Maximum input current [A] |
0.8 A |
Power supply surge protection [kV] |
±4 kV in differential mode and ±4 kV in common mode |
Ingress protection level (dustproof/waterproof) |
IP20 |
Heat dissipation mode |
Natural heat dissipation |
100% power consumption [W] |
21.43 |