Remarks |
If the upper-level circuit breaker for a device is also connected to many other devices, a C32 or above circuit breaker needs to be used. If the upper-level circuit breaker for a device is connected only to this device, a C25 or below circuit breaker can be used. |
Certification |
EMC certification Safety certification Manufacturing certification |
Chassis material |
Metal |
Static power consumption [W] |
18.74 |
Dimensions without packaging (H x W x D) [mm(in.)] |
Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442 mm x 220 mm (1.72 in. x 17.40 in. x 8.66 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442 mm x 227 mm (1.72 in. x 17.40 in. x 8.94 in.) |
Dimensions with packaging (H x W x D) [mm(in.)] |
90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.) |
Chassis height [U] |
1 |
Installation type |
Rack mounting,Desk mounting,Wall mounting |
Weight without packaging [kg(lb)] |
2.8 kg (6.17 lb) |
Weight with packaging [kg(lb)] |
3.71 kg (8.18 lb) |
Typical power consumption [W] |
33.32 |
Typical heat dissipation [BTU/hour] |
113.68 |
Maximum power consumption [W] |
- Without PoE: 38.58 W - Full PoE load: 482.55 W (PoE: 400 W) |
Maximum heat dissipation [BTU/hour] |
- Without PoE: 131.63 - Full PoE load: 1646.51 |
MTBF [years] |
48.77 |
MTTR [hours] |
2 |
Availability |
> 0.99999 |
Noise at normal temperature (acoustic power) [dB(A)] |
52.8 |
Noise at high temperature (acoustic power) [dB(A)] |
58.6 |
Noise at normal temperature (acoustic pressure) [dB(A)] |
40.1 |
Number of power slots |
0 |
Number of fans modules |
2 |
Maximum number of physical ports on the entire device |
28 |
Maximum number of 2.5GE ports |
4 |
Maximum number of GE ports |
28 |
Maximum number of FE ports |
28 |
Long-term operating temperature [°C(°F)] |
–5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.) |
Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). |
Storage temperature [°C(°F)] |
–40°C to +70°C (–40°F to +158°F) |
Long-term operating relative humidity [RH] |
5% RH to 95% RH (non-condensing) |
Long-term operating altitude [m(ft.)] |
0–5000 m (0–16404 ft.) |
Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.) |
Power supply mode |
AC built-in |
Rated input voltage [V] |
- AC input: 100 V AC to 240 V AC, 50/60 Hz - High-voltage DC input: 240 V DC |
Input voltage range [V] |
- AC input: 90 V AC to 290 V AC; 45 Hz to 65 Hz - High-voltage DC input: 190 V DC to 290 V DC |
Maximum input current [A] |
6:00 ÖÖ |
Power supply surge protection [kV] |
Differential mode: ±6 kV; common mode: ±6 kV |
Ingress protection level (dustproof/waterproof) |
IP20 |
Types of fans |
Built-in |
Heat dissipation mode |
Air cooling for heat dissipation, intelligent fan speed adjustment |
Airflow direction |
Air intake from left and front, air exhaustion from right |
PoE |
Supported |
100% power consumption [W] |
33.92 |
Maximum PoE power consumption [W] |
400 |
PoE+ power interfaces |
24 |
Full load PoE power consumption 30W (802.3at) |
13 |
Full load PoE power consumption 15.4W (802.3af) |
24 |